Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04295

Parcel: 141332200


Addresses:

8398 S OTIS DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04295

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/10/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) OK TO INSULATE
12/06/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RETRO TO BE INSPECTED AT INTERMEDIATES
12/04/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) H.D. SOUTH REAR WALL MISSING SHEAR PANEL
2) WILL CHECK RETRO AT INTERMEDIATES
3) NO ACCESS TO ROOF NAILING
11/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED CLIP NORTH SIDE 2ND FLOOR BY MASTER BATH AND CLOSET
2) H.D. NORTHWEST REAR MISSING SHEAR PANEL
3) A35 PATIO JOIST MISSING
4) NEED CLIPS BAY WINDOW 1ST AND 2ND FLOOR
5) TIGHTEN ANCHOR BOLTS POST COLUMNS (PATIO)
6) H.D. SOUTH SIDE WALL REAR MISSING SHEAR PANEL
7) 2 X 6 ? WALL HAS NO CLIPS
8) TIGHTEN ANCHOR BOLTS IN GARAGE
9) DBL H.25 GLU LAM GARAGE
10) NEED A BOLT 12" FROM SPLIT IN BOTTOM PLATE
11) STOPPED INSPECTION