Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04295
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) OK TO INSULATE |
|
12/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) RETRO TO BE INSPECTED AT INTERMEDIATES |
|
12/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) H.D. SOUTH REAR WALL MISSING SHEAR PANEL 2) WILL CHECK RETRO AT INTERMEDIATES 3) NO ACCESS TO ROOF NAILING |
|
11/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED CLIP NORTH SIDE 2ND FLOOR BY MASTER BATH AND CLOSET 2) H.D. NORTHWEST REAR MISSING SHEAR PANEL 3) A35 PATIO JOIST MISSING 4) NEED CLIPS BAY WINDOW 1ST AND 2ND FLOOR 5) TIGHTEN ANCHOR BOLTS POST COLUMNS (PATIO) 6) H.D. SOUTH SIDE WALL REAR MISSING SHEAR PANEL 7) 2 X 6 ? WALL HAS NO CLIPS 8) TIGHTEN ANCHOR BOLTS IN GARAGE 9) DBL H.25 GLU LAM GARAGE 10) NEED A BOLT 12" FROM SPLIT IN BOTTOM PLATE 11) STOPPED INSPECTION |