| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CORRECT RISER HEIGHTS ON SHORT STAIRS WEST SIDE 2) ADD BLOCKS AT DBL STUDS BETWEEN FLOORS TO CARRY LOAD TO FOOTINGS UNDER GIRDER TRUSS 3) ADD C/5 (F) AT STAIRS 4) OK TO WRAP FOR STUCCO LATHE |
|