Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T06CM04291

Parcel: 103191170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/31/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) SHEARWALLS
10/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALL GARAGE MISSING A34 CLIPS
2) ANCHOR BOLTS MISSING
3) ROOF NAILING ON EDGE BLOCKING CALLS FOR NAILS NOT STAPLES
10/24/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
10/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) SET STAPLES FLUSH WITH OSB
2) SEE DETAIL 1/10 8D NAILS 6" ON CENTER SPACING ROOF OSB INTO BLOCKING AT EXTERIOR BEARING
3) SHEARWALL INCOMPLETE REAR
4) STOPPED INSPECTION