Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED 3RD PARTY REVISION FOR USE OF TRUSS AND CONNECTIONS INSTEAD OF LEDGER-EAST END OF BLDG 2) MISSING BLOCKING AND CLIPS PER 4/A6 |