Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM04227
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2011 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/03/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. 4 X 3 MIN. WINDOW REQ'D IN WEST BEDROOM 2. 4 X 3 MIN. WINDOW REQ'D IN EXISTING BEDROOM |
|
08/07/2008 | ELECTRIC - INTERMEDIATE | Denied | 1) NEED TO TIE ALL GROUND WIRES IN RECEPT BOXES 2) NEED TO FURR OUT BLK WALL AND COMPLETE ELECTRIC WIRING 3) NEED PROTECTION PLATES ON ALL WIRE LESS THAN 1 1/4" FROM STUD EDGE 4) FUTURE LAUNDRY AND BATH NOT READY FOR INSPECTION AT THIS TIME 5) WILL NEED TO VERIFY BASEBOARD HEATERS FOR AMPS LESS THAN 20 AMPS COMBINED, DUE TO BEING ON ONE CIRCUIT |
|
01/12/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAKE UP ALL BOXES 2) STAPLE WIRES WITHIN 12" FROM BOX |
|
10/13/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) BLOCK BREAKER PANELS WEST NON BEARING WALL-NAIL 6" ON CENTER ALL ENDS 2) AB 4' ON CENTER PER PLAN 3) LAUNDRY ROOM NOT COMPLETE |