Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM04227
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2014 | FRAMING | Approved | IVRS - Inspection :* | |
03/24/2014 | FRAMING | Approved | CORRECTIONS DATED 08/20/07 ADDRESSED THROUGH OTHER INSPECTIONS (SEE APPROVALS) | |
02/03/2009 | FRAMING | Partial Approval | IVRS - Inspection :* OK TO INSULATE & SHEETROCK |
|
08/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIGHT BOX IN BEDROOM OVER LOADED WITH WIRES 2) PROTECT ALL WIRES ENTERING TO J-BOXES 3) GROUND ALL METAL BOXES 4) ROUTE ALL WIRES CONNECTED TO UNDER SIDE OF RAFTERS 5) PVC LINE WATER NOT ALLOWED IN BETWEEN FRAMING 6) EXPOSE ALL FRAME AND ELECTRIC COVERED WITH SHEETROCK 7) NAIL EXTERIOR SHEATHING AS REQUIRED PER MANUFACTURERS SPECS |