Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* THIS INSPECTION COVERS PERIMETER FOUNDATION IN ACCORDANCE WITH APPROVED PLANS AND SPEC. DETAIL S1 & S2 SHEETS SPECIAL INSPECTION FOR EPOXY CONNECTIONS PROVIDED |
|
| 04/26/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEW VAULT, PROVIDE SPECIAL INSPECTION REPORT FOR EPOXY CONNECTION ON EXISTING FOUNDATION PROVIDE VERTICAL REBAR ON CORNERS AT LEAST 3 ON EACH CORNER PROVIDE MASONRY CONTROL JOINT REBAR ON WEST AND EAST SIDES AT LEAST 2 #5 ON EACH SIDE OF MASONRY CONTROL JOINT. |