Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/01/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/27/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED ENGINEERING APPROVAL ON POST TENSION SLAB |
|
| 02/26/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE RECEPTACLE AT FRONT PORCH 2) INSTALL COVER ON A/C RECEPTACLE 3) NEED SWITCHED LIGHT SOURCE IN EACH HABITABLE ROOM 4) INSTALL SET SCREWS IN T/P 5) VACUUM BREAKERS AND ? OFF 6) PLUMB LINE SO HEATER CAN BE REMOVED WITHOUT CUTTING PIPE 7) INDICATE ? USED IN FURNACE |
|
| 02/21/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING NAILS ON POST SUPPORT AT PATIO 2) PATIO ROOF NOT COMPLETE 3) NEED TO SEAL AROUND CONDUIT AT PATIO 4) UNSHIELDED LUMINS AT BACK OF HOUSE 5) SET SCREW ANTI-SIPHON AT HOSE BIB 6) STOPPED INSPECTION |