Permit: T06CM04181

Parcel: 141311640

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM04181

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/09/2007 FRAMING Approved IVRS - Inspection :*
02/08/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE LAST INSPECTION
02/06/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) SEE LAST INSPECTION
2) BANG PLATES AT KITCHEN PENINSULA
01/29/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK MECH GARAGE
2) USE CLAMP THAT ISOLATES CU/STEEL AT UFER CONNECTION
3) H.D.'S NOT COMPLETE
4) CUT NAIL ALL PLATES
5) TWO RECEPTS WERE MOVED, WIRES NOT MADE UP, STUD OVER SPAN LIVING ROOM
6) NEED HEADER AT DUCT, INTER. BEARING 16" ON CENTER STUDS
7) PLEASE LEAVE TRUSS CALCS (CHECK INTER. BEARING)