Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T06CM04104

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Not Applicable

Date Description Inspector Results Comments
05/05/2008 ELECTRIC - INTERMEDIATE Not Applicable IVRS - Inspection :*
04/29/2008 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/14/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PARTIAL INSPECTION
#18 - MISSING LIGHT GLOBE

#17 - LIGHT TO HAVE PROPER J-BOX, WALL LAMP HAS SPLICE IN CORD, LIGHT MISSING GLOBE

#15 - REPLACE SMOKE DETECTOR

EXTERIOR:
- PANEL B - CORRECTLY IDENTIFY PANEL DIRECTORY
- GFI PROTECT EXTERIOR RECEPTACLES
- PANEL A - NOT GROUNDED, PANEL DIRECTORY NOT CORRECT
- CHECK FOR PROPERLY SIZED EQUIPMENT GROUNDS -
NEC 250.122
- NO GROUND TO PANEL "B"?
- NEUTRALS TO SHARE NO MORE THAN 2 CKTS
- MULTIWIRE BRANCH CKT'S TO TERMINATE ON SEPARATE PHASES

ELECTRICAL CONTRACTOR TO GO THROUGH PLANS AND MAKE SURE ALL CORRECT BEFORE CALLING IN FOR FINAL

440-0536