Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04057

Parcel: 141330900


Addresses:

8433 S GUPTA DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04057

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/23/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO PATCH CONCRETE AT MAS HOLDOWNS GARAGE
2) NEED FA STRAP SOUTH WALL PLUMBING
3) SHEAR PANEL S.E. CORNER NEEDS NAILS
4) NAIL MAS CLIPS AT PATIO COLUMN
5) MISSING VARIOUS RSP4 CLIP EXTERIOR WALL
6) NEED TO FIX A 34 ON EDGE BLOCKING
7) NEED TO FINISH NAILING ROOF-MISSING NAILS
12/12/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) PER SUPER NOT READY
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER