Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04057
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO PATCH CONCRETE AT MAS HOLDOWNS GARAGE 2) NEED FA STRAP SOUTH WALL PLUMBING 3) SHEAR PANEL S.E. CORNER NEEDS NAILS 4) NAIL MAS CLIPS AT PATIO COLUMN 5) MISSING VARIOUS RSP4 CLIP EXTERIOR WALL 6) NEED TO FIX A 34 ON EDGE BLOCKING 7) NEED TO FINISH NAILING ROOF-MISSING NAILS |
|
| 12/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) PER SUPER NOT READY |
|
| 12/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |