Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04044

Parcel: 141316240

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04044

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/04/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/29/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) REAR WALL MISSING TRANSFER USE ?/DT1 CLIPS WALL/TRUSS
2) MISSING #3 SHEAR PANEL 2ND FLOOR (NOTE PANEL TO GO ON THEN STRAPS)
3) QUEST. SIZE OF CMST STRAPS
4) 1ST AND 2ND FLOOR STRAPS MISSING
5) BLK S04D DOWN FROM GIRDER LOAD POINT TO 1ST FLOOR HEADER REAR WALL
6) FINISH NAILING THA HANGERS AT BEAM/TRUSS
7) MISSING NAILING UPPER ROOF
8) NEED DETAIL FOR SHEAR TRANSFER TJI
9) AT FRONT DOOR WASHERS ON HD8A