Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM04034
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/15/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/24/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) FLUX AND POSSIBLE LEAK AT FIRE CONNECTION 2) SHOWER PANS TEST OK 3) SHOWER VALVES OK 4) RECALL FOR TUB INSTALL |
|
05/01/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/30/2007 | PLUMBING - INTERMEDIATE | Partial Approval | AFTER HRS. INSP. REQ. BY MIKE 409-2568 PAID W/CHK #3142 RIVER WALK CONST. OK TO COVER WALLS CLOSET FLANGES OK RECALL FOR INSPECTION FOR SHOWER PAN LINER BEFORE TILE |
|
04/27/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PLANNING INSIDE HOUSE 2. DO NOT REDUCE TRAP ARM IN RUN 3. PROVIDE STEP LADDER FOR INSPECTION 4. DO NOT CALL FOR INSPECTION UNTIL READY 5. DO NOT COVER ANY PIPING |
|
04/26/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* WET - NO TEST LAVITORY TRAP ARM MAX. SIZE 1 1/2 HORIZONTAL WET VENTING NOT ALLOWED, UNCROSS VENT AND WASTE LINES. TIE VENTS IN ABOVE UPPER FIXTURES PLAN REVISION REQUIRED FOR USE OF AAV POINT OF VENT SHALL BE ABOVE FLOW LINE OF PIPE BANG PLATES CLOSET FLANGES OK SHWR PANS NOT YET INSTALLED |