Permit: T06CM04034

Parcel: 108252390

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM04034

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/15/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/24/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) FLUX AND POSSIBLE LEAK AT FIRE CONNECTION
2) SHOWER PANS TEST OK
3) SHOWER VALVES OK
4) RECALL FOR TUB INSTALL
05/01/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/30/2007 PLUMBING - INTERMEDIATE Partial Approval AFTER HRS. INSP. REQ. BY MIKE 409-2568
PAID W/CHK #3142 RIVER WALK CONST.

OK TO COVER WALLS
CLOSET FLANGES OK
RECALL FOR INSPECTION FOR
SHOWER PAN LINER BEFORE TILE
04/27/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PLANNING INSIDE HOUSE
2. DO NOT REDUCE TRAP ARM IN RUN
3. PROVIDE STEP LADDER FOR INSPECTION
4. DO NOT CALL FOR INSPECTION UNTIL READY
5. DO NOT COVER ANY PIPING
04/26/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
WET - NO TEST
LAVITORY TRAP ARM MAX. SIZE 1 1/2
HORIZONTAL WET VENTING NOT ALLOWED, UNCROSS VENT AND WASTE LINES.
TIE VENTS IN ABOVE UPPER FIXTURES
PLAN REVISION REQUIRED FOR USE OF AAV
POINT OF VENT SHALL BE ABOVE FLOW LINE OF PIPE
BANG PLATES
CLOSET FLANGES OK
SHWR PANS NOT YET INSTALLED