Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/14/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/11/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* DOOR LOCKED |
|
| 04/16/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NO POWER TO RECEPTACLES IN DINING AREA 2. ALL KITCHEN COUNTERTOP RECEPTACLES TO BE GFCI PROTECTED PER NEC 210.8 3. GROUND ALL SWITCHES PER NEC 404.9 4. INSTALL RECEPTACLES UNDER SINK. NEEDS BOX EXTENSION PER NEC 314.20 5. LENGTH FOR CORD TO CONNECT DISHWASHER TO BE 3FT TO 4FT PER NEC 422.16 6. CANNOT REMOVE PANEL COVER PAINTED & CAULKED TO WALL. |