Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM04029
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/11/2007 | PLUMBING - INTERMEDIATE | Approved | OK TO COVER ALL AREAS UNLESS OPTION IS TAKEN NOT USED PLUMBING TO BE PERMANENTLY BY CAPPED OFF IN THE WALL/BELOW FLOOR |
|
04/10/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* LOWER FLOORS OK TO COVER WALLS CLOSET FLANGES NOT SECURED ON CONCRETE SHOWERS NOT INSTALLED. TEST REQUIRED. COMPLETE VENT ON UPPER FLOOR, RETEST RAISE CLOSET FLANGES ON UPPER FLOORS TO CORRECT HEIGHT FOR TILE. SECURE W/BRASS SCREWS. |
|
04/06/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPORTED LEAK. DWV NOT UNDER TEST 2) KITCHEN SINK NOT VENTED PER PLAN 3) HW AND CW SUPPLY TO WASHER BOX SHALL BE 3/4" PR PLAN 4) SECURE TUBING AT W B., SECURE WATER SOFTNER DRAIN AND SECURE MV 5) INSTALL CLOSET FLANGES AT CORRECT ELEVATION |
|
04/05/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PEX REQUIRES 12" CLEARANCE FROM RECESS LIGHT SECURE TUBING AT FIXTURES, ESPECIALLY WASHER BOX 2. PERM CAP 3" IN GARAGE 3. SANITARY TEES MAY BE INSTALLED VERTICALLY ON DRAIN PIPING. 4. INSTALL CLOSET FLANGES AT CORRECT, SECURE W/BRASS SCREWS. 5. USE OF AAV AT KIT REQUIRES A PLAN REVISION 6. VENTING CROSS SECTIONAL AREA |
|
04/04/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DWV NOT UNDER TEST WATER NOT UNDER TEST SAFETY PLATES SUPPORT OR HORIZONTAL DWV T&P LIST NOT COMPLETE |