Permit: T06CM04029

Parcel: 108252350

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM04029

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2007 PLUMBING - INTERMEDIATE Approved OK TO COVER ALL AREAS
UNLESS OPTION IS TAKEN NOT USED
PLUMBING TO BE PERMANENTLY BY CAPPED
OFF IN THE WALL/BELOW FLOOR
04/10/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
LOWER FLOORS OK TO COVER WALLS
CLOSET FLANGES NOT SECURED ON CONCRETE
SHOWERS NOT INSTALLED. TEST REQUIRED.
COMPLETE VENT ON UPPER FLOOR, RETEST
RAISE CLOSET FLANGES ON UPPER FLOORS TO CORRECT HEIGHT FOR TILE. SECURE W/BRASS SCREWS.
04/06/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPORTED LEAK. DWV NOT UNDER TEST
2) KITCHEN SINK NOT VENTED PER PLAN
3) HW AND CW SUPPLY TO WASHER BOX SHALL BE 3/4" PR PLAN
4) SECURE TUBING AT W B., SECURE WATER SOFTNER DRAIN AND SECURE MV
5) INSTALL CLOSET FLANGES AT CORRECT ELEVATION
04/05/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PEX REQUIRES 12" CLEARANCE FROM RECESS LIGHT SECURE TUBING AT FIXTURES, ESPECIALLY WASHER BOX
2. PERM CAP 3" IN GARAGE
3. SANITARY TEES MAY BE INSTALLED VERTICALLY ON DRAIN PIPING.
4. INSTALL CLOSET FLANGES AT CORRECT, SECURE W/BRASS SCREWS.
5. USE OF AAV AT KIT REQUIRES A PLAN REVISION
6. VENTING CROSS SECTIONAL AREA
04/04/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
DWV NOT UNDER TEST
WATER NOT UNDER TEST
SAFETY PLATES
SUPPORT OR HORIZONTAL DWV
T&P
LIST NOT COMPLETE