Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/14/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. FILL UNUSED OPENINGS IN DISCONNECT 2. SINGLE GANG BOX RATED TO 6LBS FOR FIXTURE. PLEASE VERIFY WEIGHT OR CHANGE BOX 3. ISLAND BOXES PLASTIC WITH HOLES DRILLED INTO FOR METAL FLEX CONNECTOR ALLOWED? 4. MISSING RECEPTACLE OR PLATE - MEDIA CENTER 5. PROTECT CABLES MEDIA CENTER 6. INSTALL FAN IN BEDROOM 7. ANTI-OXIDE COMPOUND FOR ALL ALUMINUM CONDUCTORS |
|
| 09/12/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SET APPLIANCES 2. ON ROOF - IDENTIFY AC DATA PLATES, EQUIPMENT NOT TO RUN IN FRONT OF AC DISCONNECTS, STRAP FLEX 3. ELEVATOR EQUIPMENT - MAX 6' 7" TO DISCONNECT HANDLE AND CLEAR FRONT WORKING SPACE, INSTALL KO'S AS NEEDED, GROUND EQUIPMENT. |