Permit: T06CM04022

Parcel: 119421600

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
08/22/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
08/21/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOCATE (H) HOLDOWNS PER PLAN BEDROOM 4
2) NO UFER AT THIS TIME
3) UNDERGROUND ELECTRIC TO KITCHEN ISLAND NOT INSTALLED CIRCUIT 16
08/18/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS IN WRONG LOCATION FOR BEDROOM CHECK SHEARWALL PLAN FOR ELEVATION C
2) ENTRY/GARAGE HOLDOWN IN WRONG LOCATION-MUST BE IN LINE WITH SHEAR WALL
3) UFER REBAR MUST BE TIED TO 20' LONG REBAR 2" FROM SOIL
4) SECURE REBAR AT REAR PLUMBING BOX AND SEPERATE FROM SOIL