Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04015

Parcel: 116193770

Inspection Status: Approved

Inspection History: PLUMBING - PRE SLAB

Permit Number - T06CM04015

Inspection Description - PLUMBING - PRE SLAB

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2007 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
01/23/2007 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
1. PROVIDE SITE UTILITY PLAN SHOWING SEWER, WATER, AND ANY OTHER UTILITIES.
REFER TO PLAN NOTES M2.1 FOR SEWER AND WATER EXACT LOCATIONS AND INVERTS.
2. PVC DWV UNDERGROUND INSTALLED OK
WATER TEST, ONE RISER TO TEN FEET OK
OK TO COVER SUBJECT TO SITE UTILITY PLAN INCLUDING INVERTS.