Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/23/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED RED HEAD AT W. KITCHEN WALL 2) REMOVE STAPLES AT HOME RUNS, WATER MAIN, ETC... |
|
| 10/20/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 10/19/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM TRIMMER/HEADER CONNECTIONS 2) GROUT TUB HOLES 3) SUPPORT VENT 90 DEGREE IN HALL BATH 4) GAS PRESSURE READS 3 LBS 5) NEED RED HEAD AT W. KITCHEN WALL 6) SEAL PAPER HOLE ABOVE N. WINDOW AND N.E. CORNER 7) NAIL PLATE VAC LINES 8) BLOCK TUB EDGE 9) REMOVE STAPLES AT HOME RUNS, WATER MAIN, ETC. 10) FIRE BLOCK MASTER WINDOW CHASES |
|
| 10/18/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH MESH |