Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM03984
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
12/04/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* INSTALL WATER PIPING PER PLANS |
|
12/01/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - 42" MAX DISTANCE ON TRAP ARM FROM VENT TO WEIR OF TRAP. - WYE PATTERN FITTINGS REQUIRED FOR CLEANOUT EXTENSIONS (COMBO) - 3/4" WATER REQUIRED TO SERVICE BOTH KIT. AND WASHER BOX. |