Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/15/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | 1. APPLIANCES (ALL) TO BE MOUNTED IN PLACE PER MANUFACTURES INSTRUCTIONS - NEC 110.3B 2. PROVIDE GFI PROTECTION FOR ALL KITCHEN COUNTER RECEPTACLES IN REMOTE KITCHENS - NEC 210.8 3. PROVIDE GFI FOR RECEPTACLES IN SALON NEXT TO SINK PARTIAL INSPECTION, WORK IN PROGRESS CALL FOR FINAL WHEN REMAINDER OF REVISED PLANS ARE IN AND ALL PREVIOUS CORRECTIONS ARE COMPLETED |
|
| 01/14/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 10/09/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/31/2007 | ELECTRIC - INTERMEDIATE | Cancelled | IVRS - RI canceled | |
| 08/23/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK INTERIOR MAIN ENTRY AREA AND SES CORRIDOR (140, 137, 101, 102) |
|
| 08/20/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/17/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/16/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE ALL TEMPORARY WIRING THROUGHOUT BUILDING 2. CHECK SECURING/STRAPPING, KO BLANKS, ANTI-SHORT BUSHING, ETC. GO THROUGH AREA OK WALLS ROOMS #142, 145 |
|
| 08/10/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ROOMS 14?, 149, 150 & 161 |
|
| 08/03/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROOMS #152-160 EXCEPT #169 OK WALLS #147 |
|
| 07/31/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROOMS 132, 134, 135, 138, 139, 105 |
|
| 07/27/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK KITCHEN AND DINING AREA MAIN LEVEL |
|
| 07/25/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ELECTRICAL COVER #109, #108, #107, #127, #128, #129 SERVICE - NOT READY TO INSPECT POST BOND, PULL & TERMINATE FEEDERS (ALL), EGRESS DOOR TO HAVE PANIC HARDWARE, PROVIDE PERMANENT ILLUMINATION |
|
| 07/20/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROOMS 125, 126, 110 NOTE: NEED TO POST A BOND FOR SERVICE |
|
| 07/17/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SW STAIRWELL |
|
| 07/10/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 2ND LEVEL KITCHEN COVER |
|
| 07/06/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK REMAINDER OF 2ND FLOOR RESIDENT ROOMS OK N.E CORRIDOR WALLS, CEILINGS TO FIRE DOOR CALL REMAINDER OF 2ND LEVEL COMMON AREAS WHEN READY |
|
| 06/11/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 06/06/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER WALLS & CEILINGS IN RMS 212, 216, 217, 218, 219, 220, 224, 225, 226 2. HALLWAYS OK - STAIRWELLS NOT READY THIS AREA |
|
| 06/01/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROOMS 226, 225, 224, 220, 219, 218, 217, 216, 212 FIRE ALARM BOXES, CHECK ALL KO'S SPRAY ALL BOX ON FIRE ALARMS & SD'S RED PLASTER RINGS MISSING MC INSTALLED UNDER CEILING 219 MISSING RECESSED FIXTURE 217 RESUPPORT ALL LV COMM & DATA DOWN WALLS |
|
| 05/31/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 111-124 OK TO COVER |
|
| 05/29/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. ELECT. APPROVED ON 1/2 OF BUILDING EAST END UNITS 100-118 2. COMMUNICATIONS WIRING DENIED, COMMUNICATIONS WIRING PER NEC 800.6 HAS TO BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER - PROPERLY SUPPORTED AND PHYSICALLY PROTECTED PLASTIC GROMMET MISSING IN SOME AREAS, WIRING OUTSIDE OF STUD AREA - KEEP AWAY FROM METAL SHARP EDGES REVISE AND RECALL |
|
| 05/25/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROUGH ELECT RMS 111-124 1. SW GEAR ROOM REQUIRES EITHER 6' IN FRONT OF WITH 1 DOOR OR 2 EXITS - ONE AT EACH END -- 2002 NEC 110.26 C-2 2. LETTER ON MC-AP PER EE OK, ON INTERCHANGE COPPER FOR AC LETTER NEEDS TO BE SPECIFIC ON SIZES INTERCHANGED. 3. MUD RINGS ON CATV - OK (OUTLETS) 4. RM 111 THRU 124 OK TO COVER (NO STAIRWAYS) 5. CALL MONDAY FOR DATA INSTALLATIONS FOR 5/29/07 |
|
| 05/21/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* JOHN - ELECTRICAL FOREMAN (631-1040) |
|
| 05/18/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* NO INSPECTION AT THIS TIME 1. WIRING NOT PER PLAN -- PROVIDE A LETTER FROM THE ELECTRICAL ENGINEER OF RECORD STATING THAT THIS SPECIFIC TYPE OF MC IS ACCEPTABLE AND THAT NOTES 3, 4, 14, 19 DO NOT NEED TO BE FOLLOWED. LETTER TO BE STAMPED BY HIM AND SPECIFICALLY REFERENCE THE MANUFACTURER AND PART # OF MC TYPE USED. |
|
| 05/03/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PARTIAL INSPECTION ONLY 1. PROVIDE MC LISTING INFORMATION AS TO HOW IT IS LISTED TO BE USED. 2. PROVIDE BACK SUPPORT FOR RECEPTACLE BOXES AS NEEDED. 3. PROVIDE LETTER FROM ARCHITECT FOR USE OF MC 4. FINISH ALL MAKE 5. MC NOT TO BE BUNDLED MORE THAN 24" WITHOUT DERATING -- NEC 310.15 |