Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM03946

Parcel: 133425970

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/08/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
08/03/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
PROVIDE A TRAP ON CONDENSATE DRAIN
07/28/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
THE CONDENSATE DRAIN CANNOT TERMINATE DIRECTLY INTO A SEWER VENT.
LEFT GAS CLEARANCE CARD
07/25/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
15 PSI TEST IS OK
SUPPORT THE ELEC. DISCONNECT ON ROOF
SUPPORT THE GAS LINE ON ROOF
CONDENSATE CANNOT TERMINATE INTO THE SCUPPER AND CANNOT DRAIN ONTO A HARD SURFACE.
PAINT EXPOSED PVC W/LATEX PAINT.
BLOCK & CLAMP EVERY 4'.
NEED TO SEE THE NEW DRYER VENT THAT WAS INSTALLED.