Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/23/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/03/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RETRO FOR SHEARWALL HOLDOWNS GARAGE
2) OK TO CONTINUE ON OUTSIDE WALLS
09/28/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER OUTSIDE SHELL
2) STILL WAITING ON RETRO'S FOR HOLDOWNS
3) SHIM CUT 2 X 6 AT SHEARWALL
4) SHEAR TRANSFER AT INTERIOR GARAGE SHEARWALL NEEDS A.35 4' ON CENTER
09/22/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RETRO HOLDOWNS 3 IN FRONT, 2 IN BACK
2) REPLACE CUT 2 X 6 AT INTERIOR GARAGE SHEAR
3) VERTICAL BLOCKS REQUIRED UNDER OUTSIDE WALLS OF ENTRY OVERHANG PER 15/DT1
4) HINGE BRACING REQUIRED 48" ON CENTER PER 6/DT1
5) TIE ENTRY TRUSSES TO INTERIOR BEARING WALL
6) 8D NAILS REQUIRED IN BIRD BOARDS
7) NAIL HINGE BRACE BLOCKS THROUGH SHEATHING
8) 3 KING STUDS REQUIRED AT GARAGE HDR
9) STRAP GARAGE HDR PER PLAN
10) SHEAR TRANSFER AT INTERIOR GARAGE SHEARWALL