Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ITEM 5 OF 8/24/06 NOT DONE 2) OK TO DRY IN |
|
| 08/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR WALLS NOT BUILT PER NOTE 6 SHEARWALL SCHEDULE 2) NO TRUSS DRAWINGS ON SITE 3) GABLE END TRUSSES NOT CLIPPED PER 1/SD3 4) BLOCK AND NAIL ALL SHEAR PANEL ENDS AND EDGES PER PLAN 5) NORTH WEST HOLDOWN NOT ON FULL LENGTH DBL STUDS AND SPAULED. PROVIDE ENGINEER OF RECORD APPROVED REPAIR 6) SOUTH SHEAR NOT NAILED 7) ROOF OK TO DRY IN |