Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM03915
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/24/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
02/06/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PLANTERS OK |
|
01/28/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT ON RADIUS COLUMNS |
|
01/23/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 16' LIFT ON RADIUS COLUMNS | |
01/16/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT 6 COLUMNS AT RADIUS |
|
01/10/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3 COLUMNS 4' LIFT OK |
|
01/07/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 6 COLUMNS 2ND LIFT AT RADIUS |
|
12/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' LIFT ON COLUMNS |
|
12/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT ON RAKE |
|
12/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT G.L A/2.7-2.8 |
|
12/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
12/05/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
12/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT - LINE A 2.7-2.8 |
|
11/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' LIFT LINE A 2.7-2.8 |
|
11/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT LINE A-B 2.0-1.8, B 1.0-1.1 |
|
11/21/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
11/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 3RD LIFT LINE A-B 2.0, B 1.0-1.1 |
|
11/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT GRID LINE A-B-2.0 LINE B-1.0-1.1 |
|
10/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE A/2.8-2.6 A/2.0-1.8 STEM OK |