Permit: T06CM03896

Parcel: 141330940


Addresses:

8465 S GUPTA DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03896

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2007 FRAMING Approved IVRS - Inspection :*
01/10/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED 2 X NAILER AT PATIO FOR LID
2) CUT REBAR-DELETE UFER FROM SLAB
3) SHIM LET-INS
4) FIRESTOP AT MASTER BEDROOM- 2 PLACES
5) NO INSULATION BEHIND SHOWER ENCLOSURE MASTER BATH
6) SHIM ALL HEADERS
7) ANTI-SIPHON MISSING HOSE BIB
8) NO DWV TEST
9) RELOCATE SUPPLY LINE AT MASTER CLOSET
12/08/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER