Date Description Inspector Results Comments
01/23/2007 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
01/18/2007 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL 2 X BLOCKING AT STRINGER HEADER
2) MOVE FRESH AIR DUCT 10' FROM PLUMBING VENT
3) STUFF TUB HOLES AND MECH CHASE