Permit: T06CM03856

Parcel: 141331040


Addresses:

8416 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03856

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/28/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) ENGINEERED REPAIR IN FILE
12/06/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A05 TRUSS FRONT BROKEN, LOOK FOR MARKED ON FLOOR
2) TWO NAILS IN ALL WIND BRACES AT PLATES
3) ALL P.A.'S WRONG SIZE 16D'S
12/04/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RSP4 CLIP AT CORNERS
2) RSP4 CLIPS ON STUDS WITH COIL STRAPS
3) PROTECTION PLATE NORTH BOTTOM PLATE FOR PLUMBING
4) DBL STUD AT SHEAR PANEL CORNER N.W. 2ND FLOOR
5) 2 A34 AT PATIO JOIST
6) DBL STUD SHEAR PANEL CORNER S.W. 1ST FLOOR
7) GLU LAM NEEDS 2 H2.5 CLIPS
8) TRUSS BLOCKING IN KITCHEN AND DINING ROOM NOT PER 2/D6
9) NO ACCESS TO ROOF NAILING