Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03855

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/26/2007 FRAMING Approved IVRS - Inspection :*
01/24/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEM #1, #3 AND #4
2) H20 TEST OK
01/22/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP DUCT CHASE AND H20 B-VENT
2) SHIM OVER CUT LET INS 2 X 4 WALLS
3) FIRE STOP TUBS
4) C/S STRAIRS AT SHEAR WALL TO BE 36" LONG
5) CUT OFF OSB PIPE SUPPORTS FLUSH WITH CEILING
6) NO WATER TESTS
7) INSTALL FHA STRAPS ON LINE SETS