Permit: T06CM03854

Parcel: 141331020


Addresses:

8432 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03854

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KING STUDS HOLDING H.D. AT GARAGE NEEDS MORE NAILS
2) MISSING A34 CLIP AT GABLE END TRUSSES FRONT
3) MISSING GABLES BRACE BACK OF HOUSE
12/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED MORE NAILS IN KING STUD AT GARAGE, THAT IS HOLDING SHEAR PANEL H.D. BOTH SIDES
2) H.D. ON GARAGE SHEARWALL IN WRONG LOCATION PER SHEARWALL PLAN
3) A34 CLIPS GABLE END TRUSS BLOCKING MISSING PER 2/D2
4) NEED TRUSS CALC'S
12/04/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO ROOF NAILING
2) N.E. CORNER H.D. NEEDS NAILS
3) SHEAR PANEL CORNER NEEDS TO BE DBL STUDS S.W. CORNER
4) NEED TRUSS CALCS