Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03834

Parcel: 141094260


Addresses:

6350 E KOUFAX LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03834

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/16/2007 FRAMING Approved IVRS - Inspection :*
01/11/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER
01/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PERMANENT ADDRESS ON ELECTRIC PANEL
2) NO 20 AMP GFCI CIRCUIT FOR MAINTENENCE
3) NO UFER/GROUND ON PANEL
4) TRUSS REPAIR MUST BE LISTED BY ADDRESS AND ON FILE WITH CITY OF TUCSON AND HAVE CITY OF TUCSON APPROVAL STAMP
5) TRUSS FO3 HAD A 3 1/2" HOLE IN TOP CHORD BETWEEN POINTS 1 & 2. REPAIR DOCUMENT SHOWS 1" HOLE BETWEEN POINTS 2 & 3. THE SAME FO1 TRUSS HAS A 2" X 6" NOTCH BETWEEN POINTS 5 & 6 NOT LISTED ON REPAIR
6) TRUSS FO3 TWO LOCATIONS WEST OF GLB HAS 1 1/2" X 3" NOTCH IN TOP CHORD NOT ADDRESSED
7) THERE IS NO TRUSS 11 ON TRUSS LAYOUT
8) TRIPLE GIRDER BEARING IS PER REPAIR DOCUMENT EXCEPT SHEAR NAIL ON INTERIOR. HAVE ADDRESS ON REPAIR DOCUMENT AND APPROVED BY CITY
9) OK TO INSULATE-DO NOT DRYWALL TRUSS REPAIR
11/30/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWN BOLTS FRONT OF GARAGE LOOSE
2) REVERSE PITCH 2ND FLOOR 2" AT GARAGE HORIZONTAL DWV
3) SECURE WIRES AT ELECTRIC BOX/LIVING ROOM AND KITCHEN
4) FLOOR TRUSS CHORD CUT BY PLUMBING SOUTH OF WATER HEATER. PROVIDE CITY OF TUCSON APPROVED REPAIR DOCUMENT
5) STACK OF 2 X 6 ON TRIPPLE 2 X 6 BEAM CARRING SECOND FLOOR NOT ON PLAN. REVISE PLAN FOR TRIPPLE GIRDER BEARING
6) SEAL SECOND FLOOR PENETRATIONS
7) WIRE MASTER BATH FAN
8) PROVIDE 30" ATTIC ACCESS CLEARANCE
9) BLOCK RETURN AIR BOOT
10) REVERSE PITCH A/C CONDENSATE
11) WIRE BATH EXHAUST FAN
12) PROVIDE 15" SIDE CLEARANCE ON HALL TOILET
13) FIRE STOP STAIRS
11/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL SGD ON 2ND FLOOR PATIO
2) FIRESTOP HOLES THROUGH 2ND FLOOR
3) FURR OUT KITCHEN WALL AT 3" PIPE
4) SEAL VAPOR BARRIER
5) INSTALL ANCHOR BOLTS AT PLATE BREAKS
6) FIRESTOP AT LAUNDRY/FRONT PORCH
7) INSUFFICIENT FIRESTOP AT SUPPLY CHASE 2ND FLOOR
8) FRESH AIR INTAKE WITHIN 10' OF PLUMBING EXHAUST
9) STOPPED INSPECTION
11/24/2006 FRAMING Cancelled IVRS - RI canceled
11/24/2006 FRAMING Denied IVRS - Inspection :
There is no access to the site.| 920*
1) NO PLANS OR PERMIT ON SITE
2) NO ADDRESS ON SITE
11/22/2006 FRAMING Cancelled CANCELLED PER CEASAR OF SIERRA PACIFIC HOMES #349-6289