Permit: T06CM03804

Parcel: 125110830


Addresses:

3647 E 2ND ST #101


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T06CM03804

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/10/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
04/20/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/25/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK ELECTRICAL COVER -- CHECK SMOKE DETECTOR MOUNTING
09/28/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
1. INTERIOR PANELS AND BRANCH CKTS NEED TO BE GROUNDED PER 2002 NEC 250 ALSO, ADD HARD WIRED & INTERCONNECTED SMOKE DETECTORS PER CODE IN EACH UNIT.
08/22/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK COVER EXCEPT J-BOX AREA
08/04/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
1. FINISH PREVIOUS ITEMS
A REFEE WILL BE NEEDED TO BE PAID BEFORE NEXT INSPECTION.
08/01/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL ROMEX CABLES PER CONNECTOR LISTING FOR NUMBER OF CABLES
2. NEW FEEDER TO BE 4 WIRE
3. SUPPORT CABLES AT JUNCTION BOX
4. PROTECT CONDUCTORS FROM SCREWS INSIDE BOXES 314.43
5. WHAT ARE EXPOSED CONDUCTORS IN WOOD IN BATHROOMS
6. GROUND METAL BOXES.