Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OVER FRAMING VERT. TICKERS AT 48" ON CENTER EACH WAY 2) BLK OSB TURNED ON AXIS GARAGE 3) MISSED NAILING ON ROOF MARKED 4) NAIL SHEAR PANELS TO ROOF DECK 5) SUPPORT TRUSS AGE EAST END AT WEB POINTS, PLAN CALLS FOR CONTINOUS BEARING 6) PLAN CALLS FOR MECH CONNECTION HIP JACKS GARAGE 490 #'S |
|
| 10/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH NAILING OFF ROOF 2) COMPLETE ALL P.D. |