Date Description Inspector Results Comments
10/13/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/10/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OVER FRAMING VERT. TICKERS AT 48" ON CENTER EACH WAY
2) BLK OSB TURNED ON AXIS GARAGE
3) MISSED NAILING ON ROOF MARKED
4) NAIL SHEAR PANELS TO ROOF DECK
5) SUPPORT TRUSS AGE EAST END AT WEB POINTS, PLAN CALLS FOR CONTINOUS BEARING
6) PLAN CALLS FOR MECH CONNECTION HIP JACKS GARAGE
490 #'S
10/09/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) FINISH NAILING OFF ROOF
2) COMPLETE ALL P.D.