Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/12/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/31/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- YOU CANNOT CUT THE END OFF OF DOUBLE WALL VENT PIPE.
- REPLACE AS NEEDED.
- PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR
- PROVIDE AN AGA APPROVED GAS SHUT OFF VALVE.
- DOUBLE WALL VENT TO BE 2' ABOVE COOLER WITH AN APPROVED CAP.
07/03/2006 MECHANICAL - FINAL Cancelled IVRS - RI canceled