Permit: T06CM03783

Parcel: 133170630


Addresses:

350 N WILMOT RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03783

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/26/2007 FRAMING Approved IVRS - Inspection :*
06/25/2007 FRAMING Partial Approval IVRS - Inspection :*
STAIR IN COMPLIANCE WITH SPECIFIC CONNECTIONS PROVIDED BY ENGINEER RALPH D. HAAK 6/21/07 PLUS SPECIAL INSPECTIONS REPORTS PROVIDE FOR WELDING AND HIGH STR. BOLTS A325
06/18/2007 FRAMING Partial Approval IVRS - Inspection :*
NOTE: EAST STAIRWAY IN COMPLIANCE HANDRAILS AND GUARD, LANDING AND STAIR TREADS AND RISER SECTIONS 1009, 1012 & 1013 IBC 06 ALSO GUARD ON RAMPS
WEST OK TO POUR CONCRETE ON LANDING AND TREADS
MUST PROVIDE SPECIFIC DETAILS CONNECTIONS WELD/BOLTS AND SPECIAL INSP. REPORT FOR A325 H5
06/14/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
06/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTE: WELDING REPORT PROVIDED FOR EAST AND WEST STAIR LANDING
2) PROVIDE SHOP DRAWING OR RFI FOR ALL BEAM AND LEDGER CONNECTIONS
3) SPECIFICATIONS FOR BOLT CONNECTIONS
4) IN ACCORDANCE WITH CHAPTER 17 A325 HIGH STR. BOLT REQUIRES SPECIAL INSPECTION-MUST PROVIDE REPORT