Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/13/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. KITCHEN COUNTER RECEPTACLE STILL ON WITH LAUNDRY RECEPTACLE. 2. ALARM WIRING STILL NEEDS NAIL PLATES NEED TO PAY REINSPECTION FEE |
|
| 02/07/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL NAIL PLATES FOR LOW VOLTAGE/ALARM WIRING WHERE 1 1/4 OR LESS FROM STUD FACE 2) PIG TAIL NEUTRALS ON 3 WIRE HOMERUNS 3) SMOKE DETECTOR TO BE 36" MINIMUM FROM BEDROOM HVAC VENT 4) KITCHEN COUNTER RECEPTACLE NOT TO BE ON SAME CKT AS LAUNDRY RECEPT |
|
| 01/18/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |