Permit: T06CM03748

Parcel: 13312004H

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/03/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/02/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
06/27/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL CORRECT BACKFLOW PREVENTION DEVICE AT POOL FILL - PROTECT EXPOSED PLASTIC
06/20/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- PROVIDE TEMPERATURE LIMITING DEVICES FOR PUBLIC LAVATORIES.
- PRESSURE VACUUM BREAKER OR RPA ASSEMBLY REQUIRED AT BAPTISMAL FILL. PROVIDE CERTIFICATION.
- HB VAC BREAKERS
- ROOF DRAIN TERMINATIONS
06/13/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CLOSET FLANGES OK
2) FOR FINAL: BACKFLOW PREVENTION ASSEMBLY REQUIRED FOR POOL/BAPTISMAL FILL
3) INSULATE EXPOSED DOMESTIC WATER PIPING
4) INSTALL HB VAC BREAKERS
5) PROVIDE REVISED PLANS
6) INSTALL ALL FIXTURES
7) ADJUST PRESSURE IN EXP TANK TO MATCH WATER PRESSURE
05/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*