Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2007 | PLUMBING - INTERMEDIATE | Approved | ||
| 07/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 05/24/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* BELOW GRADE PIPING AT BAPTISMAL INSTALLED PER 8 1/2 X 11 UNAPPROVED PLANS W/MY INITIALS - OK TO COVER SUBJECT TO APPROVED PLAN. CALL FOR CLOSET FLANGE INSP. WHEN READY |
|
| 05/18/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEVER TEST PVC W/AIR 2. PROVIDE PROPER HYDROSTATIC TEST 3. PROVIDE APPROVED PLAN, YOUR 8 1/2'S X 11'S DIFFER FROM YOUR APPROVED DRAWINGS. 4. INSTALL HB VACUUM BREAKERS ON HOSE BIBBS. |
|
| 04/19/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* TRS 111 AND 112 OK TO COVER PROVIDE REVISION FOR WORK NOT TO BE INSTALLED FOR FINAL APPROVAL OF INTERMEDIATE & ROOF DRAINS. |
|
| 04/17/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/13/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. REDLINE CHANGES ON PLAN 2. WYE PATTERN FITTINGS REQUIRED ON VERTICAL TO HORIZONTAL AND HORIZ. TO HORIZ. CHANGES OF DIRECTION AND ON CO EXTENSIONS 3. OK TO INSULATE HW 4. T&P TERMINATION ON EXISTING WH NOT PER CODE AND REQUIRED CORRECTION. |
|
| 04/11/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 04/02/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL PROVIDE CLEANOUT FOR EWC-1A PER PLAN 2. NOTE: H/C STOOL REQUIRES 16" TO 18" SIDEWALL CLEARANCE FOR GRAB BARS 3. RAIN DRAIN PIPING TO BE CAST IRON PER PLAN SPEC WITH APPROVED COUPLING AT CONNECTION TO DRAIN BODY WITH TEST. 4. EXPOSE DEMO CAP ON OLD STOOL LOCATION. |