Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM03743

Parcel: 11941013A


Addresses:

1915 W AJO WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/30/2006 FRAMING Approved IVRS - Inspection :*
11/28/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GROUND ALL METAL BOXES
2. TAPE ELECTRICAL RISER
3. NAIL OFF FRONT PORCH HANGERS
4. REPLACE BLOWN FIREBLOCK @ HALLWAY ARCH
5. FIRESTOP MECH. CLOSET
6. INSTALL LINESET
7. STAPLE THROUGH PEX @ KITCHEN
8. BANG PLATES ON DRYER VENT
9. SEAL VAPOR BARRIER
10. TIGHTEN ALL ANCHOR BOLTS