Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM03738
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/16/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | ||
12/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL @ ALTERNATE ARQ. WALL DETAIL 8/S4.3 & S4.4 |
|
12/19/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | APPROVED PLANS TO MATCH ORIGINAL SUPPLIED SET ALL OK EXCEPT WALL FOOTINGS @ A/11 AND POPOUT AT C/7-8 |
|
11/01/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GRIDLINE C/11 CORNER B/11 LINE CROSS DETAILS ON SHEET S4.3 S4.4/8 |
|
10/24/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GRIDLINE 9/B-C DETAIL 1 ON SHEET S4.3 GRIDLINE C/9-8 DETAIL 7 ON SHEET S4.2 |
|
10/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GRIDLINE B/5-6 DETAIL F1 & F6 ON SHEET S2.0 FOOTING SCHEDULE |
|
10/19/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* WORK NEEDS TO BE DONE OR READY FOR INSPECTION. |
|
10/17/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GRIDLINE B/6-7 DETAIL 1 ON SHEET S4.2 GRIDLINE 10/A 3/4 - C DETAIL 4 ON SHEET S4.1 FOOTINGS ON GRIDLINE 10 F4 ON SHEET S2.0 |
|
10/16/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOTE: INSPECTION REQUESTED LINE B FOOTING F1 -- DENIED WORK NEEDS TO BE DONE AND READY FOR INSPECTION FOOTING F6 -- DENIED WORK NEEDS TO BE DONE AND READY FOR INSPECTION STEMWALL 1/S4.2 -- DENIED PROVIDE FORM AND COMPLETE SECTION LINE B *PROVIDE SOIL BEARING REPORT AND REVISIONS ON FOOTING F6 FOR CHANGES ON REBAR. |
|
10/11/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* NOTE: GRIDLINE A/6-11 DETAIL 3 ON SHEET S3.1 FOOTING F2 ON LINE 11 GRIDLINE B/7-10 DETAIL S ON SHEET S4.1 FOOTING F3 ON LINE 11 F2 ON LINE 11 F2 ON LINE 10 PROVIDE COMPACTATION TEST ACCORDING WITH APPROVED PLANS AND SEC. 1802 IBC |
|
10/09/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* PLEASE HAVE SOILS REPORT AT SITE. CALL ADRIAN @ 349-5388 OR LEE RAY @ 909-5154 CALL THE DAY BEFORE OR BEFORE 7AM THE DAY OF INSPECTION. |