Permit: T06CM03722

Parcel: 134041570

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/31/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
07/10/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE FACTORY COATED PIPING WITH TOOL MARKS AND FITTINGS UNDERGROUND TO 6" ABOVE GRADE PRIMED THEN TAPED TO MEET 40 MIL THICKNESS
2) PROVIDE AN APPROVED GAS SHUT OFF VALVE AT BLDG
3) PIPING ABOVE GRADE TO BE SUPPORTED AND MINIMUM 3" ABOVE FINISH GRADE
4) INSTALL WATER HEATER
5) PROVIDE BONDING OF BLDG GAS PIPING
6) EXTEND VENT FROM APPLIANCES TO 3' ABOVE TOP OF COOLER INTAKE