Permit: T06CM03714


Addresses:

1100 S RANDOLPH WY


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM03714

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
11/14/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. CLOSET FLANGES OK
2. GRAY WATER TANK & DISTRIBUTION
PIPING OUTSIDE TANKS UNDERGROUND
NO TEST PER PLAN
11/05/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. RPPBP FOR RECLAIMED WATER OK
RPPBP FOR DOMESTIC SUPPLY OK
2. 2ND FLOOR SHOWER HOLDING WATER
09/12/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
HW PIPE INSULATION AT 2ND LEVEL TR OK
AT EXTERIOR YARD WATER REPAIR - PROPER ALIGNMENT OF PVC FITTINGS IS REQUIRED AND THREAD CONNECTIONS DO NOT GET GLUE.
09/10/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
TR#208 DWV W/TEST
WATER PIPING IN TR AND OVERHEAD ABV TR OK
INSTALL INSULATION
NEED TO SEE SHOWER PAN LINER AND CLOSET FLANGE
08/31/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
THE UPPERMOST TEN FEET OF THE NEXT PRECEDING SECTION SHALL BE TESTED ON A SECTIONAL TEST SO THAT NO JOINT OR PIPE SHALL BE INSTALLED WITHOUT AT LEAST TEN FEET OF HEAD PRESSURE.
08/30/2007 PLUMBING - INTERMEDIATE Partial Approval 1" RECLAIMED WATER FROM JANITOR SINK WALL TO STOOLS IN RESTROOM ONLY. OVERHEAD HOT & COLD AND IN WALL WATER FOR RESTROOM AREA OK

1. RECLAIMED SYSTEM TO BE PROPERLY IDENTIFIED BEFORE COVERING.
2. INSULATION TO BE INSTALLED PRIOR TO COVERING (2) 3" AREA DRAINS FROM 2ND LEVEL TO EXTERIOR WATER TEST OK
08/22/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- 1ST LEVEL EAST BUILDING WASTE & VENT WATER TEST TO 2ND LEVEL OK
- WATER PIPING INSULATION 1ST LEVEL EAST BLD. OK
08/17/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT EAST BUILDING ONLY UP TO 2ND FLOOR LEVEL EXCEPT, WASHING MACHINE BOX IN MAMMAL ROOM AND AREA DRAINS ON 2ND COVER TO BE PER PLAN.
WATER PIPING 1ST LEVEL AIR TEST FROM EXTERIOR STUB OUT FOR BUILDING EAST HALF ONLY OK
08/15/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CANCELLED
06/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
(4) 2" VENTS TEST TO 6' ABOVE 2ND LEVEL DECK AT SOUTHEAST CORNER WATER TEST OK
06/04/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
AT ANIMAL HOLDING -- (4) 2" VENTS TO 16'4" OK
2" VENT IN ICE BLOCK AT BREAKROOM SINK TO 16'4" OK
05/25/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
PER SENIOR BLD INSPECTOR ICE BLOCK SHALL NOT HAVE VERTICAL PIPING IN ANGULAR SPACE.