Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03703

Parcel: 141314220

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03703

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/15/2006 FRAMING Approved
10/16/2006 FRAMING Partial Approval IVRS - Inspection :*
1) FINISH NAILING FRONT 2ND FLOOR SHEAR ABOVE GLU LAM
2) LATH NOT INSTALLED
3) A.B.'S AT ALL SHEARWALLS
4) BLK BETWEEN FLOORS AT FRONT DOOR 1ST & 2ND 4 X 6 POST
5) BANG PLATES MARKED ON FLOOR