Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM03703
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* AT INTERMEDIATE CHECK FOR 2ND CMST STRAP AT INTERIOR BATHROOM WALL. |
|
| 09/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SHEAR TRANSFER TSI LIVING ROOM 2) CMST COIL STRAPS ? |
|
| 09/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CLIP REAR TRUSS TO SHEAR 16" ON CENTER #5 2) DETAIL AT LIVING ROOM SHEAR TRANSFER AT TJI 3) QUEST CMST COIL STRAP 3" WIDE NOT A COIL STRAP |
|
| 09/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) SH 29 HANGER 2ND FLOOR BEAM TO TRUSS, BOTH SIDES OF BEAM USED 8D TECOS 2) SOUTH SIDE 2ND FLOOR WIND/BRACING MISSING 3) 2ND FLOOR BOTTOM PLATES 8" SHEAR, 12" NON-SHEAR 4) NEED HEADER SIZE FOR ?, BEDROOM CLOSET, FT04 FLOOR TRUSSES 1054 POUNDS, AT THAT BEARING 4 PT BEARING 5) ADD 2 X 4 DBL AT GIRDER BEARING 2ND FLOOR NEXT TO VERT 4 X 6 POST 6) NAIL INTERIOR SHEAR 2ND FLOOR AT BOTTOM PLATE 7) TIGHTEN BOLTS POST CAP INTER. CARRYING GARAGE INTER. BEAM 8) ALL SHEAR TRANSFERS CONFORM TO TABLE 9) 4/DT2 PLYWOOD DOWN TO BEAM 10) 2ND FLOOR SOUTH SIDE GYP SHEAR MID-SPAN BLOCKING MISSING |