Permit: T06CM03688

Parcel: 137334480


Addresses:

1773 W SAUVIGNON DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/03/2007 FRAMING Approved IVRS - Inspection :*
09/24/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/17/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH 2, 3, 4, 8 AND 9
09/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE INSPECTION WHEN UFER WAS PARTIALED 6/?
2) NAIL PROTECT PLUMBING THROUGHOUT
3) NO WATER TEST DWV SYSTEM OR POTABLE WATER
4) PROVIDE 1" CLEARANCE WATER HEATER B-VENT FROM OSB AT ROOF
5) SECURE ROMEX 8" FROM BOX MASTER SOUTH WALL
6) MISSING FIREBLOCK DINING ROOM
7) PROVIDE 12" CLEARANCE PEX FROM CANS KITCHEN
8) KITCHEN SINK MISSING 2" VTR PER PLAN
9) GROUT TUB SHOE
10) SECURE 90 VENTS ABS THRU ROOF TOP