Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/24/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 09/17/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH 2, 3, 4, 8 AND 9 |
|
| 09/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE INSPECTION WHEN UFER WAS PARTIALED 6/? 2) NAIL PROTECT PLUMBING THROUGHOUT 3) NO WATER TEST DWV SYSTEM OR POTABLE WATER 4) PROVIDE 1" CLEARANCE WATER HEATER B-VENT FROM OSB AT ROOF 5) SECURE ROMEX 8" FROM BOX MASTER SOUTH WALL 6) MISSING FIREBLOCK DINING ROOM 7) PROVIDE 12" CLEARANCE PEX FROM CANS KITCHEN 8) KITCHEN SINK MISSING 2" VTR PER PLAN 9) GROUT TUB SHOE 10) SECURE 90 VENTS ABS THRU ROOF TOP |