Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) TRUSS BRACING AND INTERIOR BEARING SHALL BE INSPECTED AT INTERMEDIATES |
|
| 07/13/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - RECHECK TRUSS BRACING & ADD PER TRUSS DRAWINGS - MISSED BEARING POINT @ INTERIOR WALL TRUSS S1A - TRUSS T-2F NOT DESIGNED FOR A HIP (PROVIDE NEW CALCS W/CITY APPROVAL) & T-3F - ADD TRUSS T-5 TO TRUSS LAYOUT INCLUDING T-5F HIP - NAIL SHEAR WALL TO PLANS |
|
| 07/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLTS MISSING ON SHEARWALL PER 2/5 2) MISSING ANCHOR BOLTS AT SPLICED BOTTOM PLATE 12" MINIMUM FROM EDGE OF SPLICE 3) CROSS BRACING ON GABLE ENDS NOT PER PLAN NEEDS TO CORRECT TO 3 COMMON TRUSSES THEN GABLE |
|
| 06/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE SLOTTED CLIPS AT SCISSOR TRUSSES AS PREVIOUSLY REQUESTED 2) DBL TOP PLATES REQUIRED 48" SPLICE PER PLAN 3) COMPLETE ALL RAT RUNS PER TRUSS SPECS 4) PROVIDE CITY OF TUCSON APPROVED TRUSS SPECS 5) PROVIDE 2 X 6 CROSS BRACING PER PLAN 6) STRAP EXTERIOR CORNERS WHERE DBL TOP PLATES ARE NOT CABIN TIED 7) STOPPED INSPECTION-REFEE WILL APPLY |
|
| 06/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM AND CLIP ALL 3 POINT BEARING TRUSSES 2) INSTALL RAT RUNS PER TRUSS SPECS 3) SLOTTED "TC" CLIPS REQUIRED FOR SCISSOR TYPE TRUSSES 4) 6" EDGE NAIL PATTERN REQUIRED AT BRACED WALL PANELS 5) NAIL SHEATHING TO DBL STUDS AT HOLDOWNS 6) MIN. 48" DBL TOP PLATE SPLICE REQUIRED PER PLAN 7) COMPLETE ROOF SHEATHING 8) PROVIDE EDGE NAILING AT BIRD BLOCKS PER PLAN 9) STOPPED INSPECTION |