Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Approval
Inspection History: BUILDING - FINAL
Permit Number - T06CM03672
Inspection Description - BUILDING - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/26/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* OK TO OCCUPY HOUSE |
|
01/16/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTSIDE LIGHT FIXTURES DO NOT MEET OUTDOOR LIGHT CODE 2) FIREPLACE HEARTH MUST EXTEND 8" BEYOND SIDES OF OPENINGS AND 16" OUTS AND NON COMBUSTIBLES 3) BALCONY MISSING GUARD RAILS 4) IMPROPER ELECTRIC CONDUCTORS BETWEEN FAN AND DISCONNECT 5) LABEL FAN HEAT STRIP 6) ISLAND OUTLETS CANNOT BE LOWER THAN 12" 7) DISHWASHER DRAIN MUST LOOP TO WITHIN 2" OF SINK FLOOR RIM 8) NO FIREPLACE WEATHER CAP |