Permit: T06CM03672

Parcel: 141094480


Addresses:

6354 E BOLDIN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03672

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/23/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/19/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ALL H/D'S OK EXCEPT WEST SIDE OF SOUTH SLIDING GLASS DOOR
2) TIGHTEN ALL RED HEADS
3) COMPLETE CAULKING AND STAPLE ENTRY
4) ONE WINDOW MISSING MASTER BATH
5) COMPLETE WIRING SWITCH BEDROOM #2
6) NO DWV TEST
7) INSTALL FHA STRAPS TOP PLATE SHOWER MASTER
8) SUPPLY TEST OK
9) NAIL STOP CONDENSATE DRAIN
10) SECONDARY CONDENSATE NEEDS TO BE TO OBVIOUS LOCATION
11) SUPPORT CONDENSATE DRAINS EVERY 8'
12) NAIL ALL NAILS FHA STRAPS
13) MAKE UP AIR SHOULD BE 10' FROM VENT OR RAISE VENT 2' ABOVE AIR INLET
09/27/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER OUTSIDE
2) WAITING ON RETRO FOR EPOXY INSTALLATION ON INTERIOR HOLDOWNS
09/21/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
09/19/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK ALL SHEAR NAILING
2) PROVIDE STIFF BACK AT INTERIOR GARAGE WALL ON FLOOR JOISTS
2) NO ACCESS
3) CHECK NAILING ON 2ND FLOOR STRAPS-NAILS ONLY PENETRATING SHEATHING
4) 1ST FLOOR H.D.'S REQUIRED 7/8" ALL THREAD ANCHORS
5) 2ND FLOOR SHEARWALLS REQUIRE 3/4" BOLTS THROUGH SILL PLATES