| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REAR TRUSS TOP CHORD NOTCHED FOR OUTRIGGERS REPAIR TOP CHORD 2) MISSING SHEAR TO BOTTOM CHORD ATTACHMENT 24" ON CENTER 3) S/E SHEAR CUT FOR BEAM 4) USE 3RD SHEAR AT REAR |