Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/05/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* FINISH ITEMS 1, 2, 3, 5, 6 DENIED BELOW |
|
| 10/03/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FINISH ALL H.D.'S 2) USE CORRECT A.B. IN SHEARWALLS 3) 2ND FLOOR SHEAR REQUIRES #7 H.D.=CMST STRAP 16 4) ROLL 45 DEGREE FITTING FOR FLAT VENT OF TOILET ON 2ND FLOOR 5) TRUSS GUSSET LOOSE IN GARAGE 6) CHECK BEARING AT HU. CORNER TOP PLATE 7) LIVING ROOM HEADER REQUIRES 2-2 X 8" 8) STUDS AT KITCHEN RANGE SHEARWALL NOT NAIL TO SHEATHING 9) H20 TEST AND DWV OK 1) NEED SHEAR TRANSFER DETAIL LIVING ROOM |